Alkaline Corrosion Inhibitor blend for Metal protection inside the CLOSED circulating system.
Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.
This closed water treatment chemicals are designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.
RXSOL-40-4011-0210 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-0210 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.
Get direct factory sale price for Corrosion Inhibitor for Cooling Towers from leading Corrosion Inhibitor for Chiller Systems manufacturers and suppliers in the UAE
Share


Corrosion Inhibitor Multifunctional Closed Chilled Systems supplier in UAE
Description
RXSOL-40-4011-210 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-210 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.
Note: The stable oxide film that is formed by RXSOL-40-4011-210 prevents corrosion caused by electrolytic action between dis -similar metals used in the system.RXSOL-40-4011 has been field tested and found to have no detrimental effects on non metallic substances such as seals, glands,packing,hoses, gaskets etc., normally used in these’systems.
Application for DG-Sets
Internal combustionengines closed circuit cooling system compressor cooling system.RXSOL-40-4011-210 incorporates superior corrosion inhibitors to prevent corrosion works by free of scale deposits.
Advantages
Prolong the life of equipment by keeping scale and corrosion free. Since RXSOL-40-4011-210 is alkaline and so will suppress acid corrosion, which would otherwise result in corrosion damage such as pitting. However, the alkalinity control is such that even if the product is accidentally overdosed, the pH of the water will remain within limits. The metals which would be affected by extremes of alkalinity or acidity are protected
- Improves generating cooling efficiency by maintaining a clean heat transfer
- Reduced maintenance and down time
- Compatible with Coolants / Antifreeze solution / Glycol .
- Friendly with Metals (Like steel, Copper, Aluminum, all alloys) & Non-metal (Rubber, Hoses, Gasket etc.)
Note: In cases where systems are contaminated with oil and/or scale they should be cleaned before starting to apply RXSOL-40-4011-210.There are suitable RX BRAND products to carry out the cleaning. Degreasing should be carried out using RXSOL-10-1005-OB and descaling by using RXSOL-11-1008-DC
Method Of Use
Note: Initial dosage for an untreated system is 9 litres of RXSOL-40-4011-210 /1000 litres of untreated distilled water.This will bring the treatment up to the minimum level of 1000 ppm nitrite.For best result and prolonged engine life add RXSOL-40-4011-210 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval.
- Properly clean the system with water and alkaline liquid , if necessary.
- The recommended dosage of RXSOL-40-4011-210 is 15.6-23.4 l/m3 of system capacity or 60.6-87 RXSOL-40-4011-210 of system capacity in all systems. Clean up the system if the system becomes contaminated with iron. Maintain 600-750 ppm nitrite as NO2. RXSOL-40-4011-210 is intended for industrial use only. It should not be fed to potable water systems
- When the product is dosed as recommended limit By buffering action of RXSOL-40-4011-210 ,pH should be maintained between 8.3 and 10 by the treatment.
Specification
Color: Clear
pH:Alkaline
Odour:None
Handling: RXSOL-40-4011-210 is an alkaline product &should be handled like other chemical Avoid contact with Eyes,Skin,in case of contact,wash with copious amounts of water immediately
How Corrosion Inhibitors Improve Cooling Tower Efficiency
Cooling towers operate with large volumes of circulating water, often containing dissolved oxygen, salts, and other impurities that can accelerate corrosion in metal components. Corrosion inhibitors are essential for protecting system integrity and enhancing operational efficiency.
Benefits of Corrosion Inhibitors in Cooling Towers:
Protects Metal Surfaces
Forms a passive film on metal parts (like pipes, heat exchangers, and tower basins), preventing corrosion by blocking reactive sites.
Maintains Thermal Efficiency
Prevents buildup of corrosion by-products (like rust) that reduce heat transfer and clog piping.
Reduces Maintenance and Downtime
Minimizes system failures due to leaks, thinning walls, and component breakdowns caused by internal corrosion.
Extends Equipment Life
Keeps expensive assets like chillers, condensers, and pumps in good condition for longer operational lifespan.
Improves Water Circulation Efficiency
Prevents blockages and uneven flow caused by rust or scale fragments circulating in the system.
Enhances Treatment Program Performance
Works in synergy with scale inhibitors and biocides for a fully optimized water treatment system
#CoolingWaterTreatmentChemicals
#CoolingWaterTreatmentChemicalsManufacturers
#CoolingWaterTreatmentChemicalsSuppliers
#CoolingWaterTreatmentChemicalsDistributors
#CoolingWaterTreatmentChemicalsUAE
#CoolingWaterTreatmentChemicalsSaudi
#CoolingWaterTreatmentChemicalsKuwait
#CorrosionInhibitorForCoolingTower
#CorrosionInhibitorSupplierinUAE
Corrosion Inhibitor Multifunctional Closed Chilled Systems manufacturer in UAE
View all-
Environmentally Friendly Corrosion Inhibitors f...
Environmentally Friendly Corrosion Inhibitors for Sustainable Cooling Water Treatment Keywords: eco friendly corrosion inhibitor GCC, green water treatment UAE, sustainable cooling tower chemicals Oman, biodegradable inhibitor Middle East Introduction With...
Environmentally Friendly Corrosion Inhibitors f...
Environmentally Friendly Corrosion Inhibitors for Sustainable Cooling Water Treatment Keywords: eco friendly corrosion inhibitor GCC, green water treatment UAE, sustainable cooling tower chemicals Oman, biodegradable inhibitor Middle East Introduction With...
-
How Corrosion Affects Energy Efficiency in Cool...
How Corrosion Affects Energy Efficiency in Cooling Towers – And How to Fix It Keywords: corrosion and energy loss, cooling tower efficiency GCC, rust inhibitor UAE, cooling water optimization Saudi...
How Corrosion Affects Energy Efficiency in Cool...
How Corrosion Affects Energy Efficiency in Cooling Towers – And How to Fix It Keywords: corrosion and energy loss, cooling tower efficiency GCC, rust inhibitor UAE, cooling water optimization Saudi...
-
Corrosion Inhibitors vs. Scaling Inhibitors – D...
Corrosion Inhibitors vs. Scaling Inhibitors – Do You Need Both in GCC Cooling Towers? Keywords: corrosion vs scaling inhibitors, scale and corrosion control GCC, cooling water chemicals UAE, inhibitor for...
Corrosion Inhibitors vs. Scaling Inhibitors – D...
Corrosion Inhibitors vs. Scaling Inhibitors – Do You Need Both in GCC Cooling Towers? Keywords: corrosion vs scaling inhibitors, scale and corrosion control GCC, cooling water chemicals UAE, inhibitor for...